Inspection Certificate

Construction
A(center): 0.12mm x 700 strands x 1 bundle
B(outer): 0.12mm x 550 strands x 6 bundles
C(sheath): ETFE extrusion(BLACK), 0.6mm thickness

 

Inspection date : –
Inspection Temperature : 10℃
Inspector : YDK QC
Judgement : Passed
Inspection Item : 0.12mm x 4,000 strands, F Class. 155℃ MW-79C / ETFE Teflon extrusion x 1 layer, Color: Black, Solderability (at 430~460℃), HF Litz Wire
Application : High-capacity Induction Heating

 

Cu & Litz Wire Inspection DATA
– Diameter of Conductor (bare copper), (0.120 ±0.003mm) : 0.12, 0.12, 0.12, 0.12, 0.12mm
– Diameter including enamel coating (0.134~0.142mm) : 0.136, 0.138, 0.138, 0.136, 0.136mm
– LITZ OD(4,500/0.12mm, less than 11.9mm) : 11.29, 11.25, 11.35, 11.46, 11.43mm
– Pin Holes of LITZ : –
– Breakdown Test of LITZ (V/sec),(at 5mA) : 1300, 1200, 1200, 1300, 1300

 

Inspection DATA of ETFE Extrusion
– Appearance : Shall not have harmful defects.
– Insulation Thickness (mm) : Approx. 0.6mm,
– Overall Diameter (mm) : 12.16, 12.22, 12.49, 12.39mm
– Dielectric Strength – Straight Sample : Shall withstand at AC 5kV/0.15sec.(Spark Test), Underwater Test at AC 2kV
– Without Aging Tensile Strength (Min. 3.00Kgf/㎟) : 3.25Kgf/㎟
– Elongation at break (Min. 100%) : 210%